The original PlayStation, released in Japan on December 3, 1994, was the first of the ubiquitous PlayStation series of console and handheld game devices.Ham Radio Software on Centos Linux Configuring multitudes of Amateur HAM Radio software for Centos6 Centos5 Linux.Known Issues, Best Practices, and Workarounds Intel Communities.Best Practices. Automatically disabling the Intel AMT Privacy Notification window.PROBLEMA Privacy Notification window automatically displays when each user logs into the Intel AMT system.RESOLUTIONEnd users can disable this window by selecting the Do not display this message checkbox.However, you can also disable the Privacy Notification window and still keep the application running by modifying a registry key.To modify the registry key Open the registry and locate this key HKEYLOCALMACHINESoftwareIntelNetworkServicesatchk.Create a new dword value named Minimize.Privacy. Icon. At.Start and set it to 0.Changing Terminal Emulation Type.PROBLEMSome vendor BIOS versions only support the display of specific emulation types.Using this command, specific ISVs will be able to redirect and emulate without issue.Linux Serial Console Terminal Program Icon' title='Linux Serial Console Terminal Program Icon' />RESOLUTIONThis command only applies to users running Altiris, HP Openview, and Microsoft SMS.On the console machine At the Start menu, select Run.In the Open field, enter CMD and click OK.A command window opens.At the command prompt, type telnet and press Enter.In the telnet session, type set term ansi or set term vt.How To Use This Manual.This is the manual for apcupsd, a daemon for communicating with UPSes Uninterruptible Power Supplies made by American Power Conversion.Linux Serial Console Terminal Program Icon Png' title='Linux Serial Console Terminal Program Icon Png' />Enter.Type quit and press Enter.Your terminal emulation type is now set to ANSI or VT1.You can re enter the telnet session at anytime and type d to verify the emulation type.NOTE If you do not properly quit the telnet session, the setting will not be saved.Customizing the Intel AMT Status dialog box.You can view the status of Intel AMT on a machine by double clicking the system tray icon and choosing Status.This dialog box displays whether Intel AMT is enabled or disabled.Linux Serial Console Terminal Program Icon GreenIt also has a hyperlink that allows the user to visit a site for more information about Intel AMT.You can customize this hyperlink to go to any site you wish.For example, you may want to modify it to point to your organizations help desk page or to the Intel v.Pro Expert Center http www.This procedure applies to Intel AMT 2.See the readme file, included in the download, for more information.Download the files to modify the registry.The files are located here http communities.DOC 1. 79. 7Save the Oem.Url. Registry. zip file to your desktop.Extract the files oementry.Customize the hyperlink.Open oementry. re in a text editor.Edit the destination hyperlink.The default entry is Oem.Urlhttp www. Rename oementry.Run the. reg file to modify the registry.Double click oementry.A cautionary dialog box displays.Click OK. An information dialog box displays that the registry was modified.Click OK. Restart the computer.Intel AMT platform may have up to 8 client certificates that can define different 8.PROBLEMSome users need to move a PC between several networks.For example, a support technician may support multiple clients that require different client certificates.RESOLUTIONUsers may install up to 8 client certificates.QA1. 31. 2Root certificate size limit is 2.PROBLEMIntel AMT is incompatible with a 4.PKI if Intel AMT systems need to validate a certificate chain containing this key size.For example, in 8. Adventist Church Day Seventh Software Companies . X networks. SOLUTIONIf a customer already has a PKI with a 4.CA and then using this to issue certain certificate for example, RADIUS.QA1. 34. 1How to hide the Intel Management Security Status IMSS tool system tray icon.SOLUTIONTo hide the IMSS system tray icon, delete the key at the following registry location HKLMSoftwareMicrosoftWindows.Current. VersionRunPiconC Program FilesCommon FilesIntelPrivacy IconPrivacy.Icon. Client. exe4.QA1. 34. 2Password issue causes Web.UI to report The system may be under attack in the event log.PROBLEMThe password policy is configured by the OEM during manufacturing.The primary setting allows a one time chagne from Adminadmin to a unique password and to have both the remote and local access synched up.If you changed the password on the remote client you will have two passwords.This is intended to allow customers to have a unique password for local access and to allow the user to change it randomly to ensure the security of the system.SOLUTIONThe system was working as designed.The local MEBx password and the Web.UI remote passwords may be different if the user has changed the MEBx password on the local machine.QA1. 38. 9Fast Call For Help Q APROBLEMQuestion 1 Is KVM Remote Control supported using Fast Call For Help Question 2 Does Fast Call For Help use Kerberos authentication Question 3 Does MicrosoftConfig.Mgr support Fast Call For HelpSOLUTIONAnswer 1 Yes, you can use KVM Remote Control after you establish a Fast Call For Help connection.Answer 2 No, Fast Call For Help only supports Digest authentication.Answer 3 No, Microsoft Config.Mgr does not support Fast Call For Help at this time.QA1. 41. Intel AMT technology does not support certain characters in FQDNPROBLEMIntel AMT does not support fully qualified domain names FQDNs ending in or.SOLUTIONAvoid using these 3 character strings at the end of the FQDN.QA1. 39. 4Intel AMT Event log includes Platform Event Traps from the BIOSPROBLEMSome events listed in the Intel AMT event log are generated by the BIOS and simply passed through to the Intel AMT event log.For example, if the system fails to boot using the PXE option, you may see a System boot failure event in the log.The source may say Intel AMT only because it was passed by the BIOS to the Intel AMT firmware.RESOLUTIONNo solution is required.This is expected behavior.QA1. 34. 5Veri. Signcertificates with MD2.RSA signature algorithm for authentication of RADIUS servers.PROBLEMThe MD2. RSA signature algorithm is not supported by the Intel AMT firmware.Veri. Signupdated their SSL certificates to use a 1.SHA 1 root in 2. Refer to Veri.Signadvisory AD1.RESOLUTIONUpdate the older Veri.Signsigning certificates to chain up to the new SHA 1 root.You do not need to update the Veri.SignRADIUS server certificate leaf certificate.QA1. 42. 3Simultaneous IDER and KVM remote control sessions cause errors on Lenovo T4.PROBLEMIf you start a SOLIDER session first, then start a KVM remote control session with VNC, the keyboard and mouse are lost in the KVM remote control session.RESOLUTIONUpdate to the latest VNC viewer and Lenovo BIOS and firmware stack.For Lenovo systems, update to package 1.For other OEMs, contact the OEM.QA1. 45. 7SOLIDER on Intel AMT 6.PROBLEMIn Intel AMT 6.SOLIDER is turned off by default.This can cause a failute in management consoles that do not open the redirection listener during the initiation of the SOLIDER session.The default state of the listerner can be changed using a MEBX setting AMT Legacy Redirection Mode, but it cannot be changed from Intel SCS 5.RESOLUTIONTo use SOLIDER with a management console that doesnt send the commands to open the redirection listener, go to the client and change the AMT Legacy Redirection Mode setting in the MEBX.QA1. 45. 0UTF 8 emulation BIOS support required for displaying Portuguese characters in SOL session.RESOLUTIONTo correctly display Portuguese in a SOL session, select UTF 8 emulation in the Intel AMT section of the BIOS.The OEM must provide UTF 8 support in the BIOS.Customers should contact their OEM for support.QA1. 43. 5How to change a client previously set to SMB mode without a hostname to Enterprise mode.PROBLEMA customer manually set SMB mode, but did not enter the client host name.The customer wants to remotely provision the client using Enterprise mode PKI.RESOLUTIONRun ZTCLocal.Agent. exe Activate as administrator on the client.This command will set the provisioning mode to Enterprise.The utility is available in the Intel AMT SDK.QA1. 43. 1Unconfigured Intel AMT system causes unwanted network traffic in 8.PROBLEMIn an uprovisioned state, whenever the 8.VLAN, the Intel ME causes undesirable network chatter if the remediation VLAN doesnt have a DHCP server.RESOLUTIONContact your OEM to determine if a firmware update is available.QA1. 44. 8No video during KVM remote control session on LenovoT4.PROBLEMThe screen will go blank when the user switches from the Nvidiagraphics to the Intel HD integrated graphics on a LenovoT4.The KVM remote control session initiated after the user switches to the integrated graphics will also show a blank screen.
|
AuthorWrite something about yourself. No need to be fancy, just an overview. Archives
November 2017
Categories |